Asante Technologies 1016-IQ Switch User Manual


 
Menus
Page 5-16
Field Description
Startup Event Configurable field; determines when the alarm is to be
triggered.
rising — alarm is triggered when the event rate
rises above the threshold.
falling — alarm is triggered when the event rate
falls below the threshold.
rising and falling — alarm is triggered when the
event rate rises above or falls below the thresh-
old.
Threshold Value Configurable field; sets the value that triggers the alarm.
Detected Value Read-only field; displays the last measurement made.
Rising Event Configurable field; displays the response to a triggered
rising event.
partitionport — partitions the target port.
sendtrap — sends a trap to the receiving trap
station.
partitionportANDsendtrap — partitions the tar-
get port and sends a trap.
sendtrapANDrequestpage — sends a trap and
sends a page to the network administrator (if the
trap receiving station is an AsantéView Manage-
ment Station).
partitionportANDsendtrapANDrequestpage
— partitions the target port, sends a trap, and
send a page to the network administrator (if the
trap receiving station is an AsantéView Manage-
ment Station).
Falling Event Configurable field; displays the response to a triggered
falling event. Options are the same as those for a rising
event (see “Rising Event” above).
Sample Interval Configurable field; sets (in seconds) the polling interval.
Note:
The shorter this time period, the more traffic on
the network.