6-8 Chapter 6: RAID conguration
8. Select
Units
from the
Virtual Drive
sub-menu, and then press <Enter>.
9. Select the units for virtual drive size from the menu, and then press <Enter>.
Configure
Initialize
Objects
Rebuild
C h e c k
DNLIN
DNLIN
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
E asy Co nfi gu rat ion - AR RAY
Virt ua l D rive(s)
LD RAID Size #Stripes StripSz
Status
0 1 148.580GB 2 64 KB
ONLINE
V ir tu al
RAID = 1
Units= MB
Size = 152146MB
DWC = Off
RA = On
Accept
SPAN = NO
Select Units For VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Select Units For
MB
GB
TB
10. When creating a
RAID 1
or a
RAID 10
set, select
DWC
from the
Virtual
Drive
menu, and then press <Enter>.
When creating a
RAID 0
set, proceed to step 12.
11. Select
On
to enable the
Disk Write Cache
setting, and then press <Enter>.
Enabling DWC can improve the performance, but with the risk of data loss.
Configure
Initialize
Objects
Rebuild
C h e c k
DNLIN
DNLIN
E asy Co nfi gu rat ion - AR RAY
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
Virt ua l D rive(s)
LD RAID Size #Stripes StripSz
Status
0 1 148.580GB 2 64 KB
ONLINE
V ir tu al
RAID = 1
Units= MB
Size = 152146MB
DWC = Off
RA = On
Accept
SPAN = NO
Disk Write Cache Setting Of
Off
On