Asus Z9PPD24 Network Hardware User Manual


 
6-16 Chapter 6: RAID conguration
6.2.4 Rebuilding failed drives
You can manually rebuild failed hard disk drives using the
Rebuild
command in the
Management Menu
.
To rebuild a failed hard disk drive
1. From the
Management Menu
, select
Rebuild
, and then press <Enter>.
2. The
PHYSICAL DRIVES SELECTION MENU
displays the available drives
connected to the SATA ports. Select the drive you want to rebuild, and then
press <Space>.
Configure
Initialize
Objects
Rebuild
C h e c k
Rebuild
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Configure
Initialize
Objects
Rebuild
C h e c k
Port # 1 DISK 77247MB HDS728080PLA380
R EB U IL D - P HY S IC A L D R IV E S
ONLIN
F A I L
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives