Avaya S8500 Network Card User Manual


 
Using the Avaya Remote Supervisor Adapter
Alerts
Avaya Remote Supervisor Adapter User Guide 35
November 2003
Critical alerts
Critical alerts are generated when one or more critical components are no longer functioning. See Table 3,
Critical alerts, on page 35 for an explanation of critical alerts.
Warning alerts
Warning alerts are generated for events that may progress into a critical level. See Figure 14, Warning and
System Alerts, on page 36.
Table 3: Critical alerts
Alphanumeric
Pager Code
Event Action
00 Temperature
irregularity
[default: Enabled]: Generates an alert if any of the
monitored temperatures fall outside the critical threshold
values. If a critical temperature setting is detected, the
S8500 Media Server shuts down. This shutdown happens
even if this field is not selected for alert notification. To
view the threshold values associated with the temperature
readings, select System Health in the navigation pane.
Under Environmentals, Temperature, click Value. A
window opens that shows the warning reset, warning, soft
shutdown, and hard shutdown thresholds for temperatures
associated with the selected component.
01 Voltage
irregularity
[default: Enabled]: Generates an alert if voltages for any of
the monitored power supplies fall outside their specified
operating ranges. If a critical voltage condition is detected,
the S8500 Media Server shuts down. The shutdown happens
even if this field is not selected to generate an alert
notification. To view the voltage operating setting, select
System Health on the navagation pane. Under
Environmentals, Voltages, click Value. A window opens
that shows the warning reset, warning, soft shutdown, and
hard shutdown thresholds for voltages associated with the
selected components.
02 Tamper [default: Disabled]: Not used in the S8500 Media Server
configuration.
03 Multiple fan
failure
[default: Enabled]: Generates an alert if two or more
cooling fans fail.
04 Power failure [default: Enabled]: Generates an alert if the power unit on
the S8500 Media Server fails.
05 Hard disk drive
failure
[default: Enabled]: Generates an alert if the S8500 hard
disk fails.
06 VRM failure [default: Enabled]: Generates an alert if one or more
voltage regulator modules (VRMs) fail.