58 CPS Installer/User Guide
Access right: SCON
Access level: APPLIANCEADMIN
Syntax
SERVER SET [IP=<ip_address>] [MASK=<subnet>] [GATEWAY=<gtwy>]
Server SNMP command
The Server SNMP command enables or disables SNMP UDP port 161 SNMP processing. When
you disable SNMP processing, you may still enable and disable traps with the Server SNMP
Trap command.
For more information, see Managing the CPS Appliance Using SNMP on page 30.
Access right: SCON
Access level: APPLIANCEADMIN
Syntax
SERVER SNMP ENABLE|DISABLE
Server SNMP Community command
The Server SNMP Community command defines read, write and trap SNMP community strings.
Community names are case sensitive.
NOTE: The default community names are “public”; if you enable SNMP, you are encouraged to change the
community values to prevent access to the MIB.
For more information, see Managing the CPS Appliance Using SNMP on page 30.
Access right: SCON
Access level: APPLIANCEADMIN
Table 5.17: Server Set Command Parameters
Parameter Description
IP=<ip_address> IP address.
MASK=<subnet> Subnet mask for the subnet on which the CPS appliance resides.
GATEWAY=<gtwy> IP address of default gateway for routing IP packets.
Table 5.18: Server SNMP Command Parameter
Parameter Description
ENABLE|DISABLE
Enables or disables SNMP processing.
Default = Enabled