Orbiting
A-2 5975597 BARCODATA 808s 110397
Orbiting Speed Toggle (only in MASTER Orbiting)
Highlight 'SPEED : SLOW' with the control disk and press ENTER to
set the ORBITING SPEED to Fast.
Highlight 'SPEED : FAST' with the control disk and press
ENTER to
set the ORBITING SPEED to Slow.
<EXIT> to return.
MASTER ORBITING
CHANGE TO MASTER
MODE : ON
SPEED : FAST
ADJUST DEVIATION
SELECT WITH OR
THEN <ENTERN>
DEVIATION ADJUST :
VERTICAL WITH OR
HORIZONTAL WITH OR
ENTER
continues to Set up Orbiting.
EXIT returns to path selection menu.
ADJUST returns to operational mode.
Orbiting Alignment
Preparation :
Before proceeding to the alignment of the Orbiting default settings,
be sure that the Horizontal Phase and the Raster shift are correctly
aligned with the Orbiting mode set to OFF.
This alignment must be performed in case of a multiple projector
installation with Master and Slave projectors in order to ensure a
correct operation of the Orbiting for all projectors.
Adjustment procedure Stand-Alone projector :
Highlight 'ADJUST DEVIATION' with the control disk and press
ENTER.
<EXIT> to return.
When adjusting the horizontal and the vertical deviation, the picture
moves in the corresponding direction, allowing the set up of the
deviation without orbiting operation.
Push the control disk to the right or down to toggle between Hor. and
Vert. deviation andjustment.
HORIZONTAL
ORBIT AMPL
70
Adjust horizontal deviation by pushing
the control disk to the left or to the right
VERTICAL
ORBIT AMPL
70
Adjust vertical deviation by pushing
the control disk up or down
SLAVE ORBITING
CHANGE TO MASTER
ADJUST DEVIATION
SELECT WITH OR
THEN <ENTERN>
DEVIATION ADJUST :
VERTICAL WITH OR
HORIZONTAL WITH OR