7. Advanced
A lamp failing to startup will be noticed by a low light output of the projector since the projector goes in single
lamp mode.
In case of a lamp error contact the local Barco authorized technician
How to clear the lamp error ?
1. Press MENU to activate the Tool bar
2. Press → to select the Lamp item
3. Press ↓ to Pull down the Lamp menu
4. Use ↑ or ↓ to select Clear lamp error
Image 7-54
5. Press ENTER
The lamp error logo is removed from the screen
7.6.6 Lamp runtime warning
What can be done ?
When the lamp has reached a predetermined runtime , a warnin
g message will be displayed on the screen. The lamp runtime
warning can be set in a range from 30 to 200 hours. The runtime warning is displayed by default at 30 hours before end of lamp
lifetime.
How to set the lamp runtime warning?
1. Press MENU to activate the Tool bar
2. Press → to select the Lamp item
3. Press ↓ to Pull down the Lamp menu
4. Use ↑ or ↓ to select Runtime warning
Image 7-55
5. Press ENTER
R5976992 ICON H250/400 13/12/2006
81