Barco SLM R12+ Projector User Manual


 
9. Service Mode
9.7.3 Setting up the Interface Standard
Set up
The communication protocol for the communication between the projector and a computer can be set on RS232 or RS422. To set
up the desired protocol, handle as follow :
1. Push the cursor key or to highlight Interface Standard.
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with or
then <ENTER>
<EXIT> to return
Menu 9-20
The actual interface standard will be displayed.
2. Press ENTER to toggle between RS232 and RS422.
Default : RS232
9.7.4 RS422 Termination
Set up
The last projector in a line should be RS422 terminated (ON position). All others in the line s
hould be in the OFF position. To change
the termination position :
1. Push the cursor key or to highlight RS422 Termination.
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with or
then <ENTER>
<EXIT> to return
Menu 9-21
The actual setting will be displayed.
2. Press ENTER to toggle between ON and OFF.
Default : ON
9.8 Network Configuration
DHCP
Dynamic host configuration protocol
What can be done?
The necessary network addresses (configuration) can be entered so that the projector can be connected to a LAN (local area net-
work).
R5976654 SLM R12+ 27/01/2005
117