Bay Technical Associates DS72 Switch User Manual


 
DS72 Host Module
15
Serial Port Configuration
The DS-Series Host modules can use different serial port configurations.
Baud Rate, Word Size, Stop Bits, Parity, Xon/Xoff, RTS Line Driver, and DTR Line Driver are
configured through the serial port using the menus. The default settings are 9600bps, 8 data bits, no
parity, one stop bit, RTS and DTR Low.
IMPORTANT: Changing the Host module serial port configuration could create a
communications lock-out if the terminal computer serial port configuration does not match the
host module.
Installed Modules :03,05
Attention Character is .........;
Disconnect Time Guard is........Disabled
Port ID Echo is.................Disabled
Unit ID is......................DS72
Network Setup :
Ethernet Address................00.C0.48.06.57.4C
IP Address......................0.0.0.0
Subnet Mask.....................0.0.0.0
Gateway.........................0.0.0.0
Inactivity Timeout (mins).......Disabled
Break Length (msecs)............350
Telnet..........................Enabled
DHCP............................Disabled
Bootp...........................Enabled
Login Setup :
Header is.......................Enabled
Connection Override is..........Enabled
SNMP Setup:
SNMP Agent is...................Enabled
SNMP Trap Host 1 Address........0.0.0.0
SNMP Trap Host 2 Address........0.0.0.0
SNMP Trap Host 3 Address........0.0.0.0
SNMP Trap Host 4 Address........0.0.0.0
SNMP Read-Only Community........public
SNMP Read-Write Community.......public
DS72 Serial Port Setup:
+----+--------+----------------+------+------+------+------+----+----+----+----+
|Port| Device | Device | Baud | Word | Stop |Parity|Xon/ Xoff|LineDrive|
| | Type | Name | Rate | Size | Bits | |Xmit|Recv|DTR |RTS |
+----+--------+----------------+------+------+------+------+----+----+----+----+
| 1 |RS-232 |EIA-232 | 9600 | 8 | 1 |None |Off |Off |Low |Low |
+----+--------+----------------+------+------+------+------+----+----+----+----+