Bay Technical Associates DS72 Switch User Manual


 
DS72 Host Module
25
Break Length
Users may configure the Host Module for a break length of 1 - 1000 milliseconds. When a user,
running a Telnet session with the Host and connected to a serial port on a DS74, sends a Telnet break
command (0xF3) to the Host Module, the serial port will send a break signal of the programmed
duration. Default is 350 milliseconds.
DHCP/Telnet/BootP
Dynamic Host Configuration Protocol (DHCP) is a communications protocol that lets network
administrators manage centrally and automate the assignment of Internet Protocol (IP) addresses in an
organization's network. Default setting is disabled.
Telnet is a user command and an underlying TCP/IP protocol for accessing remote devices. On the
Web, HTTP and FTP protocols allow you to request specific files from remote computers, but not to
actually be logged on as a user of that computer. Default setting is enabled.
NOTE: Changing this setting will logout all SSH and Telnet sessions
Bootstrap Protocol (BOOTP) is a protocol that enables the unit to obtain an IP Address from a BOOTP
server. Default setting is enabled.
Unit ID
This option allows the admin users to change the Host Module’s name.
Carriage Return Translation is.... Enabled
Enable ? (Y/N), CR for no change) :
Break Length is (msec)............ 350
Enter break length, in milliseconds (<=10000, 0 to disable) :
DHCP is...........................Disabled
Enable ? (Y/N), CR for no change) :
Telnet is.........................Enabled
Enable ? (Y/N), CR for no change) :
BOOTP is.........................Enabled
Enable ? (Y/N), CR for no change) :
Unit ID is: DS72
Enter Unit ID (64 chars max).
: DS72 Desk Test