Bay Technical Associates DS72 Switch User Manual


 
DS72 Host Module
24
NOTE: There should be no active connections while configuring the Host Module. The unit
should be reset upon completion of configuration.
Subnet Mask
The Subnet Mask is a bit mask that identifies the network portion of the IP address, allowing the Host
Module to determine whether to send a packet directly to the client or to a gateway. The Subnet Mask
consists of four bytes, each byte ranging from 0 to 255. This parameter must be programmed
before the DS-Series can be accessed through the network.
Enter the Subnet Mask (Example: 255.255.255.0), followed by <cr>. The Host Module resumes the
configuration menu. Default Subnet Mask is 0.0.0.0. If you fail to enter the Subnet Mask in dotted
decimal form, the Host Module responds again:
The Host Module responds indefinitely with the same request until the Subnet Mask is entered in the
correct form.
Gateway
The Gateway is the address of a router for connection to their networks. The Gateway address consists
of four bytes, each byte ranging from 0 to 255. If your network uses gateways, this parameter must be
programmed before the Host Module can be accessed through a network. Enter the Gateway address
(Example: 200.4.5.50), followed by <cr>. Default Gateway address is 0.0.0.0. If you fail to enter the
Gateway address in dotted decimal form, the Host Module responds again:
The Host Module responds indefinitely with the same request until the Gateway address is entered in
the correct form.
Inactivity Timeout
When this option is enabled, the Host Module will automatically disconnect, if there is no activity,
after the programmed amount of time. Default is 0 (disabled). The enabling input can be from 1 to
120 minutes.
Carriage Return Translation
Press “Y” to enable the Host Module Telnet processor to strip line feeds or nulls Translation which
follow carriage returns. Press “N” to allow the characters to pass through and press <cr> to leave this
option unchanged. Default is “disabled”.
Enter Subnet Mask in dotted decimal form :
Enter Gateway address in dotted decimal form :
Connection Inactivity Timeout is 0 minutes
Enter timeout, in minutes (<=120, 0 to disable) :
Enter 0 to disable or a number between 1 and 120 (inclusive) to set the timeout.