d. Type 5(;), the Attention Character will not echo to the screen, if it does than it may have
been changed to a character other than the semi-colon.
2. No Menu Ethernet Port:
a. Note what the CX LED is doing, refer to Appendix C.
b. Verify the Ethernet port is connected to your network via an Ethernet cable. The LINK
LED is lit for a valid connection.
c. Type 5(;) semi-colon, the Attention Character will not echo to the screen, if it does print
or Unknown character than type each character on the keyboard 5-times until you
discover the Attention character, else reset unit configuration.
3. Password not Work:
a. Password is case sensitive, check for Caps Lock.
b. Have the admin user delete the user and add back
i. Refer to DS Configuration/User Management ‘Delete a User’ and ‘Add a User’
section.
ii. Refer to Network Access Configuration/Login Setup/Manage Users
4. Network session locks up:
a. More than 4 sessions are open, close one session.
5. No Access to Configuration Menu:
a. Only one user at a time can have access. Have the other user back out of the
configuration