Belkin F1D104-OSD Switch User Manual


 
Usage
En
Keyboard “Hot” Key commands:
You can also conveniently command the OmniView
PRO to switch ports through simple
keyboard key sequences. To send commands to the OmniView
PRO, the SCROLL LOCK
key must be pressed twice within 2 seconds. You will hear a beep for confirmation. Below
are the different commands:
Switch to PREVIOUS ACTIVE port
(on the same BANK)
Switch to NEXT ACTIVE port
(on the same BANK)
Switch to the PREVIOUS BANK
(by default, selects first active port on that BANK)
Switch to the NEXT BANK
(by default, selects first active port on that BANK)
Directly switches to port Y on BANK X.
(X = {0 to 3} g = {1 to 4})
Resets the OmniView
PRO to detect “lost” mouse, keyboard
or a newly added slave unit.
You can switch directly to any port by giving the OmniView
PRO the BANK and PORT
numbers. For instance, if you press [SCROLL LOCK] [SCROLL LOCK] [2] [2], the computer on
PORT 2 of the OmniView
PRO set to BANK 2 will be selected. In the following diagram,
that is PC # 10. Hence, if you only have one OmniView
PRO, the first key (X) must be "0".
Selecting which computer to operate can be done either by On-Screen Display, the
CHANNEL button, or through keyboard “Hot” key commands. You will notice that after the
OmniView
PRO switches to another computer, the mouse will be inoperative for about 1-2
seconds. This is normal operation and ensures that proper mouse synchronization is
established.
The CHANNEL Button:
Pressing the CHANNEL button cycles you through all the ports, including inactive ports.
1234
11