Chapter 10 Configuring the NetServer
73
Another utility, DiagTools, provides an easy-to-use hardware diagnostic for
system verification, burn-in, and rapid troubleshooting. It must first be copied to
diskette and then executed from the diskette.
User Preferences
User Preferences lets you change the language and the system date and time. You
can also change the language of the BIOS.
Setup Utility
Use the Setup utility to enable or disable the integrated HP NetRAID controller.
The HP NetServer LH 4 and LH 4r factory default setting enables the integrated
HP NetRAID controller for the SCSI A port, only. For a complete discussion of
the HP NetRAID and its channels, see the Integrated HP NetRAID Controller
Configuration Guide.
CAUTION If you ever use the Setup (F2) utility to reset to system
defaults, your HP NetRAID configuration that records which
HP NetRAID channels are enabled or disable will also be
reset to its default value.
If you change the HP NetRAID configuration in the Setup
utility and then you reset to system defaults, you must re-
enable the correct HP NetRAID channels before you exit the
Setup utility.
1. Turn ON the power to the NetServer and display monitor.
2. Press the F2 function key when you see the message:
Press <F2> to enter SETUP
3. If a password has been set, provide it when prompted.
4. When the Setup Utility menu is displayed, the settings for the
integrated HP NetRAID controller are:
• Integrated HP NetRAID [Enable/Disable]
This setting enables or disables the integrated HP NetRAID
controller. To use the HP NetRAID controller, this setting is
set to Enable. To disable the HP NetRAID controller and
leave all drives under SCSI control, set this setting to Disable.