Black Box LB1350A Switch User Manual


 
Black Box®LB1350A/LB1351A
21
Network parameters
IP address: specify here the IP address you wish to assign the management
module. This parameter must be set correctly (according to your network) in
order to remotely control and monitor your device from a management station.
Subnet mask: specify the required subnet mask to use within the network.
Default gateway: specify the default gateway to be used by the management
module where applicable.
Console parameters
Baud rate: set the baud rate of communication between the Black Box®
LB1351A and the terminal. It is recommended to leave this setting at default
(9600baud).
SNMP parameters
Get community: specify the get community string for the device.
Set community: specify the set community string for the device.
Trap destination: specify the IP address of the remote manager that will
receive the traps sent by the Black Box® LB1351A
.
Trap community: specify the trap community string for the device.
System name: specify a name that identifies the device.
System location: specify the physical location of the device. Setting this
parameter properly helps to monitor the network and maintain order within it.
Contact name: specify the person (most likely system or network administrator)
that is responsible for managing and/or handling the converter.
Start up delay: specify how many seconds the management module should
wait between the appearance of the start-up screen and the system
initialization. During this time it is possible to change the management
parameters configuration.
Updating parameter storage. This may take a while...Done
Initialization...
Figure 2-3configuration complete; initialization
Your Black Box® LB1351A is now ready to be managed. The Ready LED should now
be lit steady.
Disconnect the control cable and store it properly (unless you wish to manage the
Black Box® LB1351A through a terminal).