Basic ports' status
:
# Type Link Duplex AutoNego Rate Connected
================================================
1 TP Off FDX Disabled 100M Yes
2 TP Off n/a Enabled n/a Yes
3 TP Off n/a Enabled n/a Yes
4 FO Off FDX ---- 100M Yes
================================================
Basic device status:
--------------------
VLAN: enabled
Temperature: 39C
figure 6-3 - basic status
Basic status
This status includes the basic ports’ status and the basic device status.
Basic port’s status gives the following data about each port:
Port number
Interface type (TP/FO)
Link status (On/Off)
Duplex mode (FDX/HDX)
Auto-Negotiation mode (enabled/disabled)
Data rate (10/100M)
Connection mode (connected/disconnected)
The basic device status includes:
VLAN mode (enabled/disabled)
Device’s temperature (in centigrade)
Advanced ports' status
:
# Type Tag: Insert Strip VID | Priority: Port 802.1p TOS User
=============================== |===============================
1 TP No No 0 | No No No 0
2 TP No No 0 | No No No 0
3 TP No No 0 | No No No 0
4 FO No No 0 | No No No 0
Mgmt No Yes 222 | No No No 0
=============================== |===============================
Advanced device status:
-----------------------
Test: Off
Priority ratio: Always high
Broadcast: Allow 25% broadcasts
DSCP (63 <- 0): 0x00-00-00-00-00-00-00-00
User priority: code: 0 1 2 3 4 5 6 7
prio: LO LO LO LO HI HI HI HI