Bosch Appliances C900V2 Network Card User Manual


 
Conettix C900V2 | Installation Guide | 4.0 C900V2 Configuration Setup Instructions
.
Bosch Security Systems, Inc. | 8/08 | F01U087780-01 17
7. Type 1 and press [ENTER] to set up Channel 1
configuration.
This information appears.
If the default value displayed in your
Telnet window does not match the
value listed in any of the steps below,
type the correct value and press
[ENTER].
8. At the Baud Rate prompt, press [ENTER] to
accept the default (9600).
9. At the I/F Mode prompt, press [ENTER] to
accept the default (4C).
10. At the Flow prompt, press [ENTER] to accept
the default (00).
11. Type a unique Port Number for the LAN to
which the C900V2 is connected and press
[ENTER].
12. At the ConnectMode prompt, press [ENTER]
to accept the default (CC).
13. At the Datagram Type prompt, type 01 and
press [ENTER].
14. At the IP addr prompt, type the remote IP
address used for the receiver to which the
C900V2 reports and press [ENTER].
Enter the remote IP address using
000.000.000.000 format.
15. Type the Port Number for the receiver and
press [ENTER].
If you want to enable encryption, continue with the
next step. If not, go to step 27.
If you enable encryption on the C900V2,
you must enable encryption on the
D6680 with the same key.
16. From the Change Setup menu, type 6 and
press [ENTER].
This information appears.
17. At the Disable SNMP prompt, press [ENTER]
to accept the default (N).
18. At the SNMP Community Name prompt, press
[ENTER] to accept the default (public).
19. At the Disable Telnet Setup prompt, press
[ENTER] to accept the default (N).
20. At the Disable Port 77FEh prompt, press
[ENTER] to accept the default (N).
Disabling both the telnet and port 77FE
prevents you from accessing the set-up
menu for future changes.
21. At the Disable Web Server prompt, press
[ENTER] to accept the default (N).
22. At the Disable ECHO ports prompt, press
[ENTER] to accept the default (Y).
23. At the Enable Encryption prompt, type y and
press [ENTER].
24. At the Change keys prompt, type y and press
[ENTER].
25. Type the key programmed for the receiver and
press [ENTER].
The key is 16 bytes (32 characters) long. Enter
the key using the 01-02-03-04-05-06-07-08-09-
10-11-12-13-14-15-16 format.
26. At the Enable Enhanced Password prompt,
press [ENTER] to accept the default (N).
27. Type 9 and press [ENTER] to save changes
and exit the telnet session.
To confirm that the IP address is configured
properly, use the ping utility: