Conettix C900V2 | Installation Guide | 3.0 Setup
.
Bosch Security Systems, Inc. | 8/08 | F01U087780-01 9
Table 4: Digital Dialer Protocol (DIP Switches 1 through 4, and 10)
DIP Switches
10 1 2 3 4
Dialer Format of Host Alarm Panel
ON OFF OFF OFF OFF Radionics Modem IIe and Modem IIIa
2
ON OFF OFF OFF ON Radionics Modem II
ON OFF OFF ON OFF DTMF*
ON OFF OFF ON ON DTMF* (where dialer retransmits quickly)
ON OFF ON OFF OFF BFSK (2300Hz ACK Tone)
ON OFF ON OFF ON BFSK (1400Hz ACK Tone)
ON OFF ON ON OFF FBI Superfast DTMF (2300 Hz ACK Tone) †
ON OFF ON ON ON FBI Superfast DTMF (1400 Hz ACK Tone) †
ON ON OFF OFF OFF Pulse 3/1, 3/1 Checksum (2300 Hz ACK Tone)
ON ON OFF OFF ON Pulse 3/1, 3/1 Checksum (1400 Hz ACK Tone)
ON ON OFF ON OFF Pulse 4/2 (Long 2300 Hz ACK Tone)
ON ON OFF ON ON Pulse 4/2 (Long 1400 Hz ACK Tone)
ON ON ON OFF OFF SIA Bell 103 (110/300 baud, 2016 Hz ACK Tone)
ON ON ON OFF ON Reserved
ON ON ON ON OFF ADT-SIA†
ON ON ON ON ON Reserved
OFF OFF OFF OFF OFF Reserved
OFF OFF OFF OFF ON Reserved
OFF OFF OFF ON OFF Scancom 481, 581, 681 †, ‡
OFF OFF OFF ON ON Reserved
OFF OFF ON OFF OFF Reserved
OFF OFF ON OFF ON Reserved
OFF OFF ON ON OFF Telim †
OFF OFF ON ON ON Robofon †
OFF ON OFF OFF OFF Reserved
OFF ON OFF OFF ON Reserved
OFF ON OFF ON OFF Reserved
OFF ON OFF ON ON Reserved
OFF ON ON OFF OFF SIA Bell 103 (110/300 baud, 2083 Hz ACK Tone) †
OFF ON ON OFF ON SIA V.21 (110/300 baud) †
OFF ON ON ON OFF Seriee DTMF †
OFF ON ON ON ON Seriee FSK †
* DTMF includes Contact ID, High Speed and 4/2 Express
† These formats have not been approved for UL 1610.
‡ Requires firmware version 1.12 or higher.