Conettix C900V2 | Installation Guide | 6.0 UL Standard 1610 and ULC S304 Intrusion System Installations
.
Bosch Security Systems, Inc. | 8/08 | F01U087780-01 21
Table 10: Connection Sequence – C900V2 and Generic Control Panel in Separate Enclosures
(UL Standard 1610, with or without Telephone Line)
Seq
C900V2 Connection Control Panel Connection Other Connection
1 RJ-45 PANEL connector to RJ-45 connector (telco dialer)
2 RJ-45 ETHERNET
connector
to LAN or WAN
3 – V terminal to –12 to –24 VDC (common)
4 V + to +12 to +24 VDC output
5 Install an EOL resistor for
the control panel across
OUT2-L and OUT1-R
6 OUT2-L TO OUT1-L
7 OUT2-R TO OUT1-R
8 OUT1-R to C900V2 enclosure closed-circuit
tamper switch
9 C900V2 enclosure closed-circuit
tamper switch to control panel
enclosure closed-circuit tamper
switch
10 24-hour zone input common to Control panel enclosure closed-
circuit tamper switch
11 OUT2-L to 24-hour zone input
12 Battery negative input to Battery negative terminal
13 Battery positive input to Battery positive terminal
14 AC input AC transformer
15 AC input AC transformer
NOTE: The sequence numbers appear in the diagram in Figure 12.
The optional telephone line is for programming and diagnostics only.