BridgeWave AR60X Network Router User Manual


 
AR60XInstallationManual
58000517,revB 28
4 RadioLinkStatusIndicators
Duringnormalo peration,thefollowingconditionsshouldexistattherad io:
· ThepowerLEDshouldbelit—solidgreen;
· ThefiberLEDshouldbelit—solidgreen;
· TheLinkUpLEDshou ldbelit—solidgreen;
· TheLinkQualityBERvoltageshouldbe3.3V,althoughdipsinvoltageareacceptable
duringperiodsofprecipitation.
· 10/100BaseTLEDs(eachs idenexttosocketo pening); leftshould begreenifconnected
(linkup)andrightflashingyellowindicatesactivity
Figure41:LinkUp,FiberandPowerLED’sindicatinglinkisupandoperating
Theradiosdonotrequireperiodicmaintenance.However,eachendofthelinkshouldbeperiodically
inspectedforvisibleda mageorexcessiveaccumulationofdirto ntheantenna’sradome.