![](http://pdfasset.owneriq.net/c/ca/cca2cb1c-3b58-4438-8060-c5162e9867f6/cca2cb1c-3b58-4438-8060-c5162e9867f6-bg75.png)
Confidential
5-46
(10) Remove the HR gear.
(11) Remove the two HR bush.
(12) Remove the thermistor ASSY harness from the four hooks.
(13) Remove the cup B M3x12 taptite screw, and then remove the thermistor ASSY.
Heat rolle
r
HR
b
ush
Hooks
HR
b
ush
HR gea
r
Return the hook to the
original position.
HR gea
r
Return the hook to the
original position.
Thermistor ASSY
Taptite, cup B M3x12
Hooks
Hooks
Fuser frame
Thermistor ASSY harness