Brother DCP7020 Fax Machine User Manual


 
Confidential
9-23
M-5 Insufficient output from high-voltage power supply unit
Possible cause
Step
Check
Result
Remedy
High-voltage
contact
1 Do any of the terminals on
the high-voltage contacts
have dirt or contact burns?
Yes Clean the terminals.
Yes Replace the high-voltage power
supply PCB.
High-voltage
power supply
PCB
2 Check the connections of
the connector between the
high-voltage power supply
and the main PCB are
secured correctly?
No Reconnect the connector
between the high-voltage power
supply and the main PCB.
M-6 Fixing heater temperature failure
Possible cause
Step
Check
Result
Remedy
Poor
thermistor
harness
contact
1 Is the contact of connector
CN19 on the main PCB
good?
No Reconnect the connector.
Blown thermal
fuse
2 Remove the fixing unit and
measure the resistance of
the thermal fuse. Is it open
circuit?
Yes Replace the fixing unit.
Blown
thermostat
3 Remove the fixing unit and
measure the resistance of
the thermostat. Is it open
circuit?
Yes Replace the fixing unit.
Halogen
heater lamp
failure
4 Remove the fixing unit and
measure the resistance of
the halogen heater lamp. Is
it open circuit?
Yes Replace the halogen heater
lamp.
M-7 Laser Unit failure
Possible cause
Step
Check
Result
Remedy
No Reconnect the connector
securely.
Harness
connection
failure (1)
1 Is connector CN6 on the
main PCB secured
correctly?
Yes Replace the laser unit.
No Reconnect the connector
securely.
Harness
connection
failure (2)
2 Is the connection of the
scanner motor connector
CN6 on the main PCB
secure?
Yes Replace the laser unit.