CHAPTER 5 MAINTENANCE
5-17
! Cleaning the Corona Wire
☛
☛☛
☛ 1
Press the Cover Release Button, and then open the Front Cover.
☛
☛☛
☛ 2.
Pull out the Drum Unit Assembly.
!
Caution
• We recommend that you put the drum unit Assembly on a piece of
disposable paper or cloth in case you accidentally spill the toner.
• To prevent damage to the printer from static electricity, do not touch the
electrodes shown below.
☛
☛☛
☛ 3.
Clean the Primary Corona Wire inside the drum unit by gently sliding the
blue tab from right to left several times. Return the tab to the Home position
(▲) before putting the drum unit back into the printer.
Fig. 5-10
Home Position