57
APPENDIX
• • • on • • • dim • • • off• • • blinking
*When the projection lamp reaches its end of life, the LAMP REPLACE indicator lights orange. When this indicator
lights orange, replace the projection lamp with a new one promptly. Reset the Lamp replacement counter after
replacing the lamp.
The projector is in cooling mode. It cannot be turned on until
the READY indicator lights green.
Projector Condition
LAMP
REPLACE
orange
Indicators
READY
green
LAMP
red
WARNING
TEMP.
red
The projector detects an abnormal condition and cannot be
turned on. Unplug the AC power cord and plug it again to turn
on the projector. If the projector is turned off again,
disconnect the AC power cord and contact the dealer or the
service center for service and checkup. Do not leave the
projector on. It may cause electric shock or a fire hazard.
The projector is in the Power management mode.
✽
✽
✽
The temperature inside the projector is abnormally high.
The lamp cannot light up. (The projector is preparing for stand-
by or the projection lamp is in cooling mode. The projector
cannot be turned on until the cooling process is completed.)
The lamp cannot light up. (The lamp has been cooled down
enough and the projector is in stand-by mode and ready to be
turned on with the POWER button.)
✽
The projection lamp reaches its end of life.
Replace the lamp and then reset the Lamp replacement
counter. The indicator is turned off.