17
Initialization
TE-2200/2400 Dealer's Manual
Initialization
Machine initialization procedure
1. Plug the power cord into an AC outlet.
2. Hold down <JOURNAL FEED>.
3. Turn the mode switch to PGM position.
4. Release <JOURNAL FEED>.
You should see “0000000000” on the display.
If 10 zeros are not shown or another character are shown,
immediately set the mode switch to OFF and restart from
the beginning of this procedure.
5. Enter 11-digit program code from the worksheet.
6. Press <SUBTOTAL> to register the program code.
(Wait until beep twice.)
7. Press <SUBTOTAL> to register the program code.
D
11
D
10
D
9
D
8
~ D
3
D
2
D
1
s
refer to Worksheet (Initialize)
REG2 X1
REG1 Z1
OFF X2/Z2
RF
PGM
RECEIPT JOURNAL
FEED FEED
RECEIPT
FEED