CONFIGURING the SERVER
33
Both PCIe slots (slots 1 and 2) and the mezzanine card slot are supported
Only a single VIC card (the half-height Cisco VIC 1225 PCIe card) is supported and it
must be installed in slot 1 (the full height slot).
Only a single Cisco UCS 3.0 TB MLC Fusion ioDrive2 card is supported and it must be
installed in slot 1 (the full height slot).
Up to two of the other Fusion ioDrive2 cards (1205-, 785- and 365-GB versions) are
supported and can be installed in either slot 1 or 2, although an adapter may be
needed when installing one of these half-height cards in slot 1 (the full-height slot).
Other considerations for the Cisco VIC 1225:
Supports 10G SFP+ optical and copper twinax connections
The server supports installation of one Cisco VIC 1225 card and it is supported only
in PCIe slot 1.
Requires that the server has CIMC firmware version 1.4(6) or later installed. There is
a heartbeat LED on the top of the card that indicates when firmware is active.
To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS
Manager 2.1(0) or later, the minimum card-firmware and uboot image level is
2.1(0.306).
To help ensure that your operating system is compatible with the card you have selected,
check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html