Cisco Systems SFS 7000P Switch User Manual


 
5-6
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
OL-10853-01
Chapter 5 Managing the Switch
Displaying System Information
In the OperStatus field, a status of up indicates that the fan is operating correctly within the power supply
module.
In the Speed field, the integer represents a percentage. The percentage changes based on the ambient
temperature of the unit and increases as the temperature rises.
Using the Sensors Tab
Use the Sensors tab to view the operating status of the temperature sensor of the system.
(See Figure 5-11.)
Figure 5-11 Health Status Sensors Window
In the OperStatus field, a status of up indicates that the sensor functions properly.
The temperature fields show temperatures in Celsius. The Current Temp field shows the current internal
temperature. The Alarm Temp field shows the temperature at which the system goes above its internal
temperature limit. The Shutdown Temp field shows the temperature at which the system powercycles.
For operating and non-operating temperatures, see Table A-1 on page A-1.
Displaying System Information
You can use CLI commands to monitor the power supplies, fans, and sensors.
Displaying Power Supply Information
To display information about the power supply, enter the show power-supply command.
SFS-7000P# show power-supply
===============================================================
Power-supply Information
===============================================================
ps type oper-status utilization voltage
----------------------------------------------------------------------------
1 AC up 50 12
2 AC up 50 12
===============================================================
Power-supply Seeprom
===============================================================
product pca pca fru
ps serial-number serial-number number number
---------------------------------------------------------------
1 200000 820000 820000 1
2 200000 820000 820000 1