Citizen Systems CT-S310 Printer User Manual


 
- 126 -
GS g 0 m nL nH
CT-S280 CT-S300 CT-S2000 CT-S4000 BD2-2220 CT-S310
support model
PMU2XXX
[Function] Initializing maintenance counter
[Code] <1D>H<67>H<30>H<m><nL><nH>
[Range] m=0
20(nL+nH×256)70(nL=20215070nH=0)
[Outline] [The specification which is common to the model]
Set the value of resettable maintenance counter specified to 0.
nL, nH are used to set the maintenance counter number to (nL+nH×256).
Counter Number
Counter Unit
Hex. Decimal
14 20
Paper-feed lineline
15 21
Head powering count times
32 50
Auto-cutter drive count times
46 70
Product operation timehours
[Caution] • This command, if used frequently, may destroy NV memory, thus write command to NV memory
shall be used less than 10 times/day as a guideline.
• Along with processing this command, during data-writing to NV memory, printer BUSY may occur.
During the printer BUSY, to stop receive processing, this printer prohibits the data sending
(including real-time command) from host.