Citizen Systems CT-S310 Printer User Manual


 
- 287 -
4.2.5 MSW5
MSW5-1 Buzzer
[Outline] Select the enable/disable of buzzer.
OFF(0) ON(1)
Buzzer Valid Invalid
ON (1) OPERATION: Disable buzzer
When an error occurs or memory switch setting is changed manually, no buzzer sounds.
OFF (0) OPERATION: Enable buzzer.
When an error occurs or memory switch setting is changed manually, the buzzer sounds.
MSW5-2 Basic vertical calculation pitch
[Outline] Select the basic calculation pitch in the paper feed direction.
OFF(0) ON(1)
Line Pitch 360 406
ON (1) OPERATION: Basic vertical calculation pitch is set to 1/406 inch.
Line-feed length is 3.75mm by default.
OFF (0) OPERATION: Basic vertical calculation pitch is set to 1/360 inch.
Line-feed length is 4.23mm by default.
MSW5-3 USB mode
[Outline] Select USB mode.
OFF(0) ON(1)
USB Mode Virtual COM Printer Class
ON (1) OPERATION: Operated as Printer class
OFF (0) OPERATION: Operated as virtual COM class
MSW5-4 Reserved [Fixed to OFF (0)]