iDP3550/3551 User’s Manual
40
CITIZEN
12. WINDER CONNECTOR
12.1 Specifications of Winder Connector
(1) Winder drive signal
The winder drive signal is output synchronous with the LF signal.
(2) Electrical characteristics
1) Drive voltage: 24 V DC
2) Drive current: 0.8 A at maximum
12.2 Connector's Pin Configuration
No. Signal Function
1 VPX Winder drive power
2 WD Winder drive signal
3 FG Frame Ground
4 FG Frame Ground
Connector used : 5045-04A (MOLEX)
Applicable connector : 5209-04 (MOLEX) or equivalent
CAUTION : • This connector shall be used for Auto Winder AW-3 only.
Do not connect any other device.
12.3 Drive Circuit