iDP3550/3551 User’s Manual
71
CITIZEN
VT
[Function] Vertical tab
[Code] <0B> H
[Outline] This command feeds the paper to the next vertical tab position. It cannot be fed unless the
vertical tab position has been set. If the current position is equal to or greater than the
maximum set vertical tab position, it will be fed to the head of the next page.
ESC "B" [n]k NUL
[Function] Setting the vertical tab position
[Code] <1B>H <42>H [n]k <00>H
[Range] 1 ≤ n ≤ 255
1 ≤ k ≤ 16
[Outline] This command cancels the already set vertical tab positions and sets new vertical tab
positions. They are set in the ascending order and ends with <00>. Up to 16 vertical tabs
can be set. If the tab setting position <nk> is equal or smaller than the preceding set
position <nk-1>, it is assumed that setting of the vertical tabs has been completed.