MSA Fabric Switch 6 Management Utility
3-44 Modular SAN Array Fabric Switch 6 User Guide
COMPAQ CONFIDENTIAL
Writer: Kim L. Miller File Name: d-ch3 MSA Fabric Switch 6 Management Utility.doc
Codename: Millebourne Part Number: 230934-002 Last Saved On: 7/17/02 7:52 AM
Backup/Restore Tab
The Backup/Restore window is accessed by clicking the “Backup/Restore” tab of the
System Information display. It consists of one panel titled: “Backup and Restore
Settings.” Using this interface, you can save the current configuration parameters of
the switch to a named TFTP server. You can also restore any previously saved
configuration to the switch.
To perform either a backup or restore operation, enter the correct parameters for
“Backup/Restore File Set” and “TFTP Server IP Address” and click either the
Backup or Restore button.
CAUTION: TFTP servers will create new files with modified filenames, resulting in
‘restore’ not retrieving the expected file. Be sure to verify that the TFTP server you
are using overwrites existing files to avoid this issue.
The following figure is an example of the Backup/Restore tab.
Figure 3-30: Backup/Restore tab