Connect Tech Blue Heat/Net Sync User Manual
Revision 0.03 19
In the above example, a rapidly flashing CPU LED during the boot up process signifies the Blue
Heat/Net Sync has experienced an error. Port LEDs 1 through 4 signify which error has
occurred. In this case, LED 2 and 3 are on, so the error code is 6. The chart below defines the
error details for each error code.
Table 4: LED Error Codes for Blue Heat/Net Sync
Error Code and Event
Details
Suggested Corrective
Action
1. Loader code in flash is erased.
The regions of flash memory which hold
the loader code are both erased. (There
are two redundant loaders in flash that
can be run).
This may occur in when
there are ESD
disturbances or in
electrically noisy
environments. If this error
persists it may be a
hardware issue.
Contact Connect Tech.
2. Loader code in flash has a bad CRC.
The regions of flash memory which hold
the loader code both have CRC errors.
(There are two redundant loaders in flash
that can be run).
See corrective action for
error code 1.
3. RAM copy of loader code has a bad
CRC.
The loader code is copied to RAM
before execution. This error is shown if
the RAM copy has a CRC error.
See corrective action for
error code 1.
4. Configuration Data Space (CDS) areas
have corrupted data (CRC failure).
The CDS is copied from flash to RAM
during the beginning of the loader code.
If a CRC error is detected in the RAM
copy, this error is shown.
See corrective action for
error code 1.