Set the IP Address Using the Web Configuration Manager
NOTE: If you use the Windows Configuration Manager
and use Auto Discover to locate your Blue Heat/Net
Sync on the network, you can right-click and launch the
Web Configuration Manager from there.
You only need to use the route add command if you
choose not to use the Configuration Manager found on
the CD that accompanied your Blue Heat/Net Sync unit.
From the command prompt of your computer, run: route add A.B.C.0 mask 255.255.255.0 <current
IP of your host machine> Be sure to replace the .D from the Blue Heat/Net Sync‟s IP with a 0
(zero). Open your browser and put the Blue Heat/Net Sync‟s IP in the address bar (i.e. A.B.C.D)
This will open the WCM. Log in (default login is wcm and the default password is password)
and assign the static IP or change the IP to 0.0.0.0 if you are using a DHCP assigned IP.
Set the IP Address Using the Serial Configuration Manager
Insert your CD into the computer and complete the following steps:
1. Once your CD has been inserted, the Driver/Software Installation menu should appear. If it
doesn‟t, double-click on ctisetup.htm.
2. Click View in the Blue Heat/Net Sync Software section and then Connect in the Serial
Configuration Manager section. This will launch HyperTerminal that comes with Windows XP.
3. Unplug the power to the Blue Heat/Net Sync and plug it back in. Light indicators 1 to 4 will
blink sequentially. This sequential flashing will last for 30 seconds. You must log in during
this window.
4. During this sequential flashing, type the word password into the HyperTerminal window. Be
careful you do not miss the window of opportunity to enter the password.
5. You now have access to the Serial Configuration Manager (SCM). An scm> prompt is ready
to accept commands. If you do not see this prompt, unplug the power and repeat the steps above.
If you wish to set a dynamic IP address enter the following:
net dhcp=yes
save
exit
If you wish to set a static IP address, enter the following, substituting xxx.xxx.xxx.xxx with the
static IP you wish to assign:
net mip=xxx.xxx.xxx.xxx
save
exit
Close the HyperTerminal. You may now disconnect the DB-25 cable from your PC and connect
it to any serial device
.