Connect Tech Blue Heat/Net Sync User Manual
28 Revision 0.03
[my_ip= | mip=]
[server_ip= | sip=]
[gateway_ip= | gip=]
[subnetmask= | snm=]
[broadcast_ip= | bcip=]
[dns_ip=]
[domain=]
[host name=1 host=]
[tcp=]
[mac=]
[dhcp=]
Description: Establishes the network settings.
Options: network= | net=
Sets the “network” portion of the IP address into my_ip, server_ip and
gateway_ip. The address entered is masked by the subnet mask setting before
being applied. This command is a shortcut for quickly setting all the IP
addresses of the unit. See note below.
my_ip= | mip=
This sets the IP address of the Blue Heat/Net Sync unit (default is 192.168.42.1).
See note below.
server_ip= | sip=
This sets the Server IP address. This address determines the address of the
Server to use when the Bootp and tftp mode is enabled (see boot command), and
also as the default Server address to use for the update commands (default is
0.0.0.0). See note below.
gateway_ip= | gip=
This sets the Gateway IP address. This address is used when the Bootp mode is
enabled, default is 0.0.0.0. See note below.
subnetmask= | snm=
This sets the Subnet mask IP address. (The default is 255.255.255.0) See note 1.
broadcast_ip= | bcip=
This sets the Broadcast IP address. This is used when the Bootp mode is
enabled. (The default 255.255.255.255). See note below.
dns_ip=
This sets the IP of Domain Name Server. (The default is 0.0.0.0). This must be
set to update the Blue Heat/Net Sync firmware automatically from Connect
Tech‟s anonymous ftp server.
domain=
This sets the Domain name of the unit. (The default is blueheat.net)
Host name=1 host =
This sets the Host name of the Blue Heat/Net Sync unit. (The default is
BHNssssssss, where “ssssssss” is the serial number of the unit).
tcp=
This sets the base TCP port number used for Host TCP/IP and UDP/IP
communications. The default is 49152 (0xC000)