5. Cannot obtain an operating system
image (uClinux) to run.
This will occur when any of the enabled
boot sources (flash or BOOTP/TFTP or
TFTP) fail to obtain a valid compressed
operating system image to run.
Check network
connections, server
computer or your unit's
settings.
This error occurs if TFTP
booting is enabled and the
Blue Heat/Net Sync
cannot download the file
from the server.
Contact Connect Tech if it
persists.
6. Unexpected return from the uClinux
operating system.
This error occurs if the operating system
returns back to the loader.
See corrective action for
error code 1.
7. CDS re-programming failure.
Certain CDS items are updated during
the bootup. If a failure occurs during the
re-programming of the flash, this error
will occur.
See corrective action for
error code 1.
8. Boot count could not be incremented
in flash memory
This error is usually caused by a Flash
memory failure.
Contact
Connect Tech.
9. No ports found
This message usually indicates a UART
component failure.
Contact