Syncing to an AES/EBU Reference
If you want to synchronise your system to an AES/EBU Reference from a
Master Clock (such as the dCS 992) or other stable source, do the following:
do this: Set the Master Clock sample rate to match the source (probably 44.1 or
48kS/s).
do this: Connect either an AES/EBU or Wordclock output from the Master Clock to the
clock input on the source equipment and ensure it is locked.
do this: Connect another AES/EBU output from the Master Clock to the AES Ref Loop
IN connector on the dCS 974 rear panel.
do this: Scroll down the Sample Rate Conversion menu to Sync Source and press
the
button. Scroll down the list to AES Loop Terminated and press Set.
The Unlocked indicator will light for a few seconds, then turn off as the unit
re-locks.
do this: Proceed to Step 3.