Multi-channel Sample Rate Conversion – with multiple sample rates out
A dCS 992 Master Clock
6
can also be used to sync up the source and more
than one set of units, all at different sample rates, and be the master. DVD
production may require different sample rates for different channels – this set up
will give real time 48 kS/s rear channels and 96 kS/s front channels from a
multi-channel 44.1kS/s source. See Figure 16 overleaf. For all dCS 974 units,
set the Multiple Channel Sync option to On. They will all set up as slaves.
Make sure that all the other settings are the same on each unit in a group.