38 Using the System Setup Program
Integrated Devices Screen
Table 2-4 lists the options and descriptions for the information fields that appear on the Integrated
Devices screen.
Serial Communication Screen
Table 2-5 lists the options and descriptions for the information fields that appear on the Serial
Communication screen.
Table 2-4. Integrated Devices Screen Options
Option Description
Integrated SAS Controller
(Enabled default)
Enables or disables the integrated SAS controller. This option appears only if a SAS
controller is installed.
Integrated RAID
Controller
(Enabled default)
Enables or disables the integrated RAID controller. This option appears only if a
SAS RAID controller is installed.
Embedded SATA
(Off default)
Allows the integrated SATA controller to be set to Off or ATA Mode.
IDE CD-ROM Controller
(Auto default)
Enables the integrated IDE controller. When set to Auto, each channel of the
integrated IDE controller is enabled if IDE devices are attached to the channel.
Diskette Controller
(Auto default)
Enables or disables the system's diskette drive controller. When Auto is selected,
the system turns off the controller when necessary to accommodate a controller
card installed in an expansion slot. You can also configure the drive as Read-Only,
or Off. When using the Read-Only setting, the drive cannot be used to write to a
disk.
User Accessible USB Ports
(All Ports On default)
Enables or disables the system’s user accessible USB ports. Options are All Ports
On, Only Back Ports On, and All Ports Off.
Embedded Gb NIC
(Enabled with PXE
default)
Enables or disables the system's integrated NIC. Options are Enabled without
PXE, Enabled with PXE, and Disabled. PXE support allows the system to boot
from the network. Changes take effect after the system reboots.
MAC Address Displays the MAC address for the integrated 10/100/1000 NIC. This field does not
have user-selectable settings.
TOE Capability Displays the TCP/IP Offload Engine (TOE) feature status of NIC.
Table 2-5. Serial Communication Screen Options
Option Description
Serial Communication
(Off default)
Options are On with Console Redirection via COM2, and
Off.