32 About Your System
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 158.
E1812 Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920 iDRAC6 Upgrade
Failed.
optional iDRAC6
upgrade has failed.
See "Getting Help" on
page 169.
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 169.
E1A15 SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 169.
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 169.
E2010 Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
"Troubleshooting System
Memory" on page 153.
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 153.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
R310HOM.book Page 32 Thursday, March 4, 2010 1:03 AM