Dell E07S002 Server User Manual


 
About Your System 41
Current boot mode
is set to UEFI.
Please ensure
compatible
bootable media is
available. Use
the system setup
program to change
the boot mode as
needed.
The system failed to boot
because UEFI boot mode is
enabled in BIOS and the
boot operating system is non-
UEFI.
Ensure that the boot mode is
set correctly and that the
proper bootable media is
available. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 53.
Embedded NIC
x
and
NIC
y
:
OS NIC=
<ENABLED
|DISABLED>
,
Management
Shared NIC=
<ENABLED
|DISABLED>
The OS NIC interface is set
in BIOS. The Management
Shared NIC interface is set
in management tools.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC" on
page 147.
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Mouse or keyboard cable is
loose or improperly
connected.
Reseat the mouse or
keyboard cable.
Defective mouse or keyboard. Ensure that the mouse or
keyboard is operational. See
"Troubleshooting a USB
Device" on page 146.
Gate A20 failure. Faulty keyboard controller;
faulty system board.
See "Getting Help" on
page 169.
Invalid
configuration
information -
please run SETUP
program.
An invalid system
configuration caused a
system halt.
Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and UEFI Boot Manager" on
page 53.
Table 1-3. System Messages (continued)
Message Causes Corrective Actions
R310HOM.book Page 41 Thursday, March 4, 2010 1:03 AM