Dell H810 Server User Manual


 
80 Management Applications for PERC Cards
Controller Management Actions
Table 5-8 describes the actions you can perform on the Ctrl Mgmt screen.
Table 5-8. Controller Management Options
Option Description
Enable Controller
BIOS
Select the option to enable the controller BIOS. If the boot
device is on the RAID controller, the BIOS must be enabled.
Disable the BIOS to use other boot devices.
In a multiple controller environment, you can enable BIOS on
multiple controllers. However, if you want to boot from a
specific controller, then enable the BIOS on that controller
and disable it on the other controllers. The system can then
boot from the BIOS-enabled controller.
Enable BIOS Stop
On Error
Select the option to stop the system BIOS during bootup if
there are BIOS errors. The option enables you to enter the
configuration utility to resolve the problem.
Select Bootable
Device
Select the option to specify a virtual disk as the boot disk on
the controller.
NOTE: For PERC H310 the option may be a Virtual Disk or
Non-RAID drive.
The option is displayed if you have built virtual disks.
Enable Auto Import Attempts to import every online foreign configuration during
boot without having the need to access the BIOS
Configuration Utility (<Ctrl><R>).
Factory Default Select the option to restore the default settings for the options
in the Settings box.