Dell HHB Laptop User Manual


 
Error Code Message Information
LCD Message CPU <
number
> has a thermal trip. Check CPU heat sink.
Details The processor temperature increased beyond the operational range.
Action Review logs for fan failures, replace failed fans. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat-sink.
CPU0002
Message CPU <
number
> has failed the built-in self-test (BIST).
Action
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see Getting Help.
CPU0003
Message CPU <
number
> is stuck in POST.
Action
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Reduce system configuration to minimum memory and remove
all PCI devices. If system completes POST, update system BIOS.
reinstall memory and PCI one component at a time to meet the
original configuration.
3. If the issue persists, see Getting Help.
CPU0004
Message CPU <
number
> failed to initialize.
Action
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see Getting Help.
CPU0005
Message CPU <
number
> configuration is unsupported.
LCD Message CPU <
number
> configuration is unsupported. Check CPU or BIOS
revision.
Details System is unable to boot or may run in a degraded state.
Action Review the technical specifcations for supported processor types.
CPU0006
Message Unrecoverable CPU complex error detected on CPU <
number
>.
Details System is unable to boot or may run in a degraded state.
79