EMC 300002039 Server User Manual


 
You cannot use this switch in conjunction with
the -user|-u, -password|-p ,and-scope|-s switches.
-port 443|2163
Specifies the Navisphere Management
Server port number. The default is 443.
-directory outputdirectory
Specifies the directory to which you want to deposit the report on the
server. This switch is required only if you are running the server utility
from the CD. Otherwise the report is automatically saved to the
Navisphere Server Utility installation directory.
Note: If the server utility is installed on your server and you specify a directory,
the directory you specify will override the server utility’s installation directory.
After uploading the HA report
In addition to running the server utility to validate server high
availability, we strongly recommend that you perform the following
manual checks.
Verify support of software and hardware —Makesurethatyou
have verified that all software and hardware is supported according
to EMC’s E-Lab™ Interoperability Navigator and support matrices.
Note:Thisto
ol does not verify that you are running supported switch
firmware, n
or does it check that you are using redundant switches
(recommend
ed).
Upgrading s
torage–system software — If you are about to perform
astorage-s
ystem online software upgrade or you added an HBA, a
LUN, or chan
ged connectivity (added a path or changed zoning):
z Make sure th
at you have validated all software and hardware
are support
ed and interoperable according to EMC E-Lab
Interoper
ability Navigator and support matrices.
z Ver ify t ha
t all LUNs (virtual disks) that your servers will access
during the
upgrade are under path management software
control. F
or servers running PowerPath and DMP, see the
Failover
Software section on the Details tab of the report and
40