EMC DS-16B2 Switch User Manual


 
2
Setting the Switch Status Policy
2-9
Basic Switch Configuration Procedures
Setting the Switch Status Policy
There are seven parameters that determine the status of a switch:
Number of faulty ports
Missing GBICs (i.e., Small Form Factor Pluggable transceivers)
Power supply status
Temperature in enclosure
Fan speed
Port status
sgroup ISL status
Only one parameter needs to pass the MARGINAL or DOWN
threshold to change the overall status of the switch.
Do not modify these parameters unless so notified by EMC Customer
Service.
Viewing the Policy
Threshold Values
To view the switchStatusPolicy threshold values:
1. Log in to the switch as the admin user.
2. At the command line, enter the following command:
switch:admin> switchStatusPolicyShow
The current overall switch status policy parameters:
Down Marginal
----------------------------------
FaultyPorts 1 0
MissingGBICs 0 1
PowerSupplies 2 1
Temperatures 3 1
Fans 3 1
PortStatus 0 0
sgroup ISLStatus 2 1