Departmental Switch Model DS-16B2 Fabric OS Procedures Manual
Displaying Error Logs and Status
For more information on the portErrShow command, refer to the
Departmental Switch Model DS-16B2 Fabric OS Reference Manual.
Displaying the Error Log of a Switch
There are two ways to display the error log of a switch:
Display the error log one page at a time
Display the error log all at once
To display the switch error log one page at a time:
1. Log in to the switch as the admin user.
2. At the command line, enter the following command:
ErrShow
To display the switch error log all at once:
1. Log in to the switch as the admin user.
2. At the command line, enter the following command:
ErrDump
Displaying the Switch Status
The switch status can be Healthy/OK, Marginal/Warning, or Down.
The overall status of a switch is determined by the status of several
individual components within the switch. For more information on
how the overall switch status is determined, refer to the
switchStatusPolicySet command in the Departmental Switch Model
DS-16B2 Fabric OS Reference Manual.
To display the overall status of a switch:
1. Log in to the switch as the admin user.
2. At the command line enter the following command:
switchStatusShow
The status of the switch should be Healthy/OK. If the status is
Marginal/Warning or Down, the components contributing to this
status are displayed.