Emerson 400501-05 Server User Manual


 
5
Installation
AC Line Filters
The AC line filters used during Control Techniques’ compliance testing are listed below.
These filters are capable of supplying the drive input power to the specified drive under
maximum output power conditions.
Alternately, Control Techniques has also seen good results with the following line filters:
AC Line Filter Installation Notes
EMC criteria can be met in installations where multiple drives are supplied through a
single filter, however, it is the installers responsibility to verify EMC compliance.
Questions on this subject should be directed to the filter manufacturer.
It is critical that you keep the filter inputs routed away from any electrical noise sources
to prevent noise from being induced into them and carried out of the enclosure.
Epsilon E Series Schaffner Part # Control Techniques Part # Rating
Eb-202, Eb-203
FN2070-10/08 960307-01 10A, 240V, 1 Ø
EN-204 FS5278-16/08 960305-01
16A, 240V, 1 Ø
Eb-205 EN-208 FS5278-16/08 960305-01
EN-214 FN-258/16 960304-01 16A, 480V, 3 Ø
Drive Part # Rating
EN-204
Corcom 20EQ1 20A, 240V, 1 ØEN-208
Eb-202, Eb-203, Eb-205
Eb-202 Schaffner FN 2070-6-06 6A, 240V, 1 Ø