Emerson 400501-05 Server User Manual


 
44
Epsilon Eb Digital Servo Drive Installation Manual
ECI-44 External Connector Interface
The ECI-44 allows access to all command and input and output signals. The ECI-44 should
be mounted close to the drive and away from any high voltage wiring. The ECI-44 comes
complete with the hardware necessary for mounting to most DIN rail mounting tracks.
Figure 39: Dimensions of ECI-44
Note
Shield connection points are connected to the shell of the 44-pin “D” connector on the
ECI-44. Also, the shield connection points of the ECI-44 are also designed to provide a
point for cable strain relief.
Use tie wraps to provide a strain relief and a ground connection at the shield connection
points.
If you do not wish to use the DIN rail mounting hardware, the ECI-44 can be disassembled
and the mounting clips removed.
The ECI-44 wire range is #18 to 24 AWG stranded insulated wire.
Note
Wiring should be done with consideration for future troubleshooting and repair. All
wiring should be either color coded and/or tagged with industrial wire tabs. Low voltage
wiring should be routed away from high voltage wiring.