Installation
Input/Output and Drive Enable Wiring
Drives are equipped with five optically isolated input lines (one is dedicated to a drive enable
function) and three optically isolated output lines. They are designed to operate from a +10
to 30 VDC source. All inputs and outputs are configured as sourcing. You are responsible for
choosing a load that will limit each output’s current to less than 150 mA.
Figure 18: Epsilon Input/Output Wiring Diagram
Epsilon Only
The I/O connector is a 26-pin male connector on the front of the drive. Control Techniques
offers a low profile interface plug and cable (EIO-xxx) for connections.