Emerson MVME147 Computer Hardware User Manual


 
Assign Alternate Sector Packet (SCSI)
7-35
7
CL Complete List
Clear and no defect list is supplied. Use existing grown defect
list, no user list is supplied.
Clear and defect list is supplied. Use existing grown defect
list, add user list to the grown list.
Set and no defect list is supplied. Do not use existing grown
defect list, no user list is supplied.
Set and defect list is supplied. Do not use existing grown
defect list, use user list as the complete defect list.
DP Disable Primary List of Defects
Clear. Use manufacturer’s primary list if the controller/drive
supports it.
Set. Do not use manufacturer’s primary list.
DC Disable Certification Process
Clear. Use certification if the controller/drive supports it.
(Drive is certified at format time.)
Set. Do not use certification.
SF Stop Format
Set. Format even if a controller/drive defect list cannot be
accessed.
Clear. Stop formatting when any of the controller/drive
defect lists cannot be accessed.
R Reserved
76543210
CL DP DC SF R R R R
$15 xxxxxxxx SCSI function ($10 =
format, $14 = assign
alternate
$16 000000xx Interrupt level (7
through 0) (0 = polled
mode